10 Fraser Avenue, Johnsonville
Homewise Report - August 2026
Character and charm - but several weathertightness issues need prompt attention.
The building inspection provided found this bungalow to be "well put together" with a sound timber frame, good insulation, and modern TPS wiring. But three weathertightness risks - missing scribers on the west elevation, insufficient ground clearance on the south wall, and a deck gap too narrow for drainage - create rot risk that compounds quickly if ignored. The garage is in poor condition and requires a decision before it becomes a liability. The roof coating is overdue. None of these are dealbreakers on a character property with this kind of bones, but a buyer needs to act in the first 6 months and budget meaningfully for exterior works in years 2–4.
This is a single-storey, timber-framed character bungalow from the 1940s–60s era, located in Johnsonville. The property sits on a concrete perimeter wall foundation with concrete piles. Cedar weatherboards are bevel-backed and directly fixed to the frame. The pressed metal tile roof has a pre-coated steel finish that was showing weathering at the time of the building inspection provided.
Character features are a genuine highlight: native tongue-and-groove hardwood floors throughout, stained glass windows with leadlight detail, a decorative brick fireplace, and native hardwood joinery. These add meaningful value and should be carefully maintained.
The heat pump meets Healthy Homes heating requirements. The hot water system is a gas infinity heater - efficient and modern. Electrical wiring throughout the main house is TPS (Thermoplastic Sheathed) - the current standard. The garage has disconnected TRS wiring (old and unsafe), and a possible asbestos fuseboard.
- Borer: Borer holes were noted in the subfloor and roofspace in the building inspection provided - common in properties of this era. No large-scale infestation was identified, but this should be monitored annually. Watch for fresh frass (fine sawdust). The native T&G floors are particularly valuable and worth protecting.
- Grey polybutylene plumbing: This property has a mix of copper and grey polybutylene pipes. Grey polybutylene (common in 1980s–90s NZ installations) is known to become brittle and crack over time. Monitor for signs of moisture in the subfloor and behind walls. Budget for eventual repiping.
- Single-glazed windows: All windows are native hardwood single-glazed with putty glazing. In a High/Very High wind zone, capillary action can draw water in through the putty joint during severe storms. Maintain the putty bond as part of regular maintenance.
- Asbestos: The garage fuseboard may contain asbestos-containing material (ACM). Do not disturb. Any demolition or renovation work on the garage requires a licensed asbestos assessor to inspect first.
- No building consents on record: The property has building permits (pre-1993 system) but no building consents on the Council record. Any significant future building work will require consents under the current Building Act 2004.